Onorm en 501 teil 2 europanormung weiterhin gultig da dtz. Classification using test data from reaction to fire tests and onorm en 773 textiles and textile products burning behaviour curtains and drapes classification scheme, has necessitated. European standard en 5011 provides the reaction to fire classification procedure for all products and building elements. Publisher osterreichisches normungsinstitutaustrian standards. Classification using data from reaction to fire tests from nsai.
Classification using data from reaction to fire tests. S1, d0 class b1 flame retardant austria onorm en 501. Classification using test data from reaction to fire tests this european standard provides the reaction to fire classification procedure for all construction products, including products incorporated within building elements. S1, d0 q1 limited smoke development holland nen en 501. The various original reclaimed wood surfaces were tested and classified in standardized test arrangements. Reaction to fire in accordance with onorm en 5011 e thickness mm 10 20 30 40 50 60 70 art. Europaische baustoffklassifizierung nach din en 501 hagebau. En 5011 fire behaviour in conjunction with flameretardant laminated plywood even veneered.
The issuance of austrian standards onorm en 5011 fire classification of construction products and building elements part 1. Bs2,d0 highly noncombustible coating material for seagoing vessels in accordance with solas 7488 chapter ii2 iso 109935 toxicity testing. Should you require any further information, please do not hesitate to contact your local. Classification using data from reaction to fire tests from sai global. In addition, the abovementioned product is classified with regard to its smoke growth rate production as.
Sollten sich grundlegende pruf oder bewertungskriterien andern. Classification using data from reaction to fire tests from sai. Bodenbelage werden in einem gesonderten klassifizierungssystem nach en 5011 behandelt. In a complex and lengthy process, we have had the fire behaviour of our products classified in accordance with onorm en 5011. Europaische baustoffklassifizierung nach din en 501. The validity of the classification report is extended up to 5 years.
Standards en 5011 and din 4102 part 1, separate building materials. European standards also include a section eurocodes. Europaische klasse nach din en 5011 1,2 bauprodukte, ausgen. Standards referenced by this book show below hide below onorm h 6038. The classification report is valid until 2 december 2023. Begriffsbestimmungen, anforderungen, prufungen 19720101 19821201 19970301 20040101 nachfolgedokument norm norm norm zuruckziehung onorm en 5012. Pursuant to onorm en 5011 the abovementioned construction product is classified bs2, do in respect of the reaction to fire performance. In the event that fundamental testing or assessment criteria change, the. Fire behaviour class onorm en 5011 a1 the present tool supports you in the planning of masonry made of ytong thermoblocks and applied thermal insulation with multipor, but it does not replace the own technical examination by the user with respect to the intended use and suitability. According to this standard, reaction to fire is the response of a product in contributing by its own decomposition to a fire to which it is. En 438, type f hpl according to en 438, type s, p spread of flame bs 476. Mastertop 1785 waterborne, thin epoxy system july 2016 page 1 of 4.